GiveAwayBuildings.com GiveAwayBuildings.com
Toll Free
(877) 283-9510   
GIVEAWAY SALE - TIME REMAINGIN:
7 hours, 32 minutes
FOR THESE LISTED BUILDINGS & PRICES!! Details
GiveAwayBuildings.com
FEATURES / DEFINITIONS
ALL BUILDINGS ARE NOT THE SAME.
CHECK OUT OUR STANDARD FEATURES.
    Highlights of our building include:
  • 20 yr. Paint warranty (4 wall color choices, 16 trim color choices)
  • 50 yr. structural warranty
  • 80,000 psi. Strength sheeting (resistant against ding and dents)
  • 26 ga., w/ 1 ¼" Attractive sheeting profile
  • Solid-Beam Construction
  • Pre-welded clips for ease of erection (most manufactures only supply the clips)
  • Pre-punch Components
  • Girt and Purlins Overlap for additional structural integrity
  • Framed openings have C-section jambs and headers for easy installation of Over-head doors
  • Submerged Arc/Welded Frames
  • Fully trimmed at gable, corners and eaves for a more finished look and additional protection from dust and wind seepage
  • All necessary columns, beams, rafters, girts, purling, sheeting, nuts and bolts.
  • We use matching finished, self drilling, self-tapping lifetime fasteners on all roof and wall panels
  • All Premier Buildings will comes with cable bracing and/or /portal frame and/or rack brace which will add strength and rigidity.
  • 100% U.S. made materials (our commitment to support American workers)
  • One set of approval drawings and 3 sets of plans
PRIMARY FRAMING
(Consisting of columns for sidewalls and rafters for roof)
SOLID I-BEAM construction for optimum strength.
Material used is minimum 50,000 and 36,000 p.s.i. yield strength. (Some Manufacturers use 35,000 p.s.i. yield strength material, which is not as strong.)

Frames are single bead, continuous are welded by automatic welding machines to help insure quality control and then a factory primer coat is used to help protect them during the erection process.

ENDWALL FRAMES AND COLUMNS are either cold formed, mill-rolled or built-up "I" sections depending on design requirements.

SECONDARY FRAMING
GIRTS (in sidewall) and PURLINS (in roof) are 8" or 10" to meet design requirements.
Cold rolled Z-section, 12 to 16 ga. ASTM A-57, 50,000 p.s.i. yield material is used to provide maximum strength.

Bypass girt system overlaps at sidewall columns forming a continuous "beam" for extra strength.

PURLINS are top-mounted on the rafter with a varied lap of 1ft to 5ft for strength and cost savings in erection labor. Maximum purlin spacing is 5ft on center.

EAVE STRUT is a cold-formed C-section that is rolled for the appropriate roof pitch to help insure weather tightness at the eave.

RAKE ANGLE is a continuous angle supplied for the attachment of the sheeting at the rake of the building for ease of installation.

BASE ANGLE is a continuous angle supplied for the attachment of the base of the sheeting to the concrete. Base Angle is to be attached to the concrete with rams-sets or equivalent anchors by others.

BRACING
Diagonal galvanized cable bracing is supplied for roof and walls to remove longitudinal load from the structure. Galvanized cable is used rather than solid rod to prevent the bracing from "sagging" under its own weight and is easier to install.

Angle Flange Bracing is provided for the connection of the rigid frame to the purlins and girts. This makes sure that allowable compressions are adequate for any combination of loadings.

FRAMED OPENINGS have cold-formed C-section jambs and headers to help insure easy installation of over-head doors, etc.

SHEETING
26 Gauge - 80,000 P.S.I. yield material standard. Some manufacturers use lower yield strength material, which is less resistant to damage from hail or other impacts.

ALL COIL STEEL has a minimum of G-90 class galvanization (1.25oz hot dipped) on each side to help prevent deterioration of the steel sheeting.

DEEPER HIGH-RIB with more frequent corrugations. Provides extra strength.

SIPHON GROOVE is rolled into all High-Rib roof sheeting to provide a built-in "gutter" system every 36" for the entire length of the building helping to prevent water from migrating into the roof system.

OPTIONAL ARCHITECTURAL PANEL configuration is available for walls, mansard systems, soffit material, etc., to add an aesthetic appeal to your building.

FASTENERS
STRUCTURAL BOLTS meet requirements of ASTM Standards.
A-325 for primary frame connections.
A-307 for secondary framing.

SELF-DRILLING AND SELF-TAPING FASTENERS are pre-assembled with neoprene washers and metal caps to help insure weather tightness.

CLOSURES
CLOSED CELL NEOPRENE STRIPS with self-adhesive backing used to help seal building. Located at eave, gable and base of building to help provide weather tightness. Pre-formed shapes to match panel configurations providing a tighter seal.

1 ½" SHEETING NOTCH at base of concrete where panel sits is designed into every building. Sheeting notch provides an air infiltration stop on blanket insulated building.

SEALANTS
SEALANT for roof sidelaps, endlaps and flashing at gable is provided to help insure weather tightness. Nominal 3/8" x 1/8" thick pressure sensitive tape sealant for ease of installation.
RIDGE CAP
LONG OVERLAP to help prevent water from siphoning into building.
TRIM AND FLASHING
All buildings are fully trimmed at rake (gable) corners and eaves, with standard trim material for a more finished look. Not only improves look of building but is an additional deterrent to moisture, insects and dirt getting into building.
GiveAwayBuildings.com
GiveAwayBuildings.com
GiveAwayBuildings.com
GiveAwayBuildings.com
Home | Standard | Deluxe | Features | Photos | About Us | FAQ | Owner Statement | Search | Eagle Prayer | Checkout | Contact
Please verify your local building code. It is the customer's responsibility to verify local codes.
GiveAwayBuildings.com
GivewayBuilding.com © 2008 GiveAwayBuildings.com. All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.
Use of this Web site constitutes acceptance of the GiveAwayBuildings.com Terms and Privacy Policy.

OrderStorm.compowered by

GiveAwayBuildings.com